Call us (03) 9544 1477
15 Fulton Street Oakleigh South Victoria Australia 3167 Mon to Fri: 8.30 AM to 4.30 PM
“BROWN” ‘SILENT’ WATER HEATER STEAM OPERATED
A simple, robust, long lasting unit which allows the rapid heating of water in open tanks by steam, without the noise which is prevalent when steam is ejected direct into cold water.
The steam is directed through the body of the water and there is little loss through condensation of the steam.
The “Brown” ‘Silent” Water Heaters have no couplings or parts to come loose. They are particularly free of maintenance and are of one piece construction in Bronze or Stainless Steel.
USES:
For open tank heating of water by steam in Creameries, Dairies, Chemical Plants, Breweries and general process operations.
INSTALLATION:
Steam supply pipe must be at least as large as heater steam inlet. A 10″ or 12″ length of pipe must be screwed into the discharge end (large end) of the heater. The heater must be well submerged below the level of the liquid being heated and the discharge nipple pointer to the remote part of the tank to permit thorough mixing before the liquid is returned for circulation.
| Heater | Steam Pipe | Discharge Pipe | ||
| BSP | mm | BSP | mm | |
| H | 1/2″ | 15 | 3/4″ | 20 |
| J | 3/4″ | 20 | 1″ | 25 |
| K | 1″ | 25 | 1 1/4″ | 32 |
| L | 1 1/4″ | 32 | 1 1/2″ | 40 |
| M | 1 1/2″ | 40 | 2″ | 50 |
| N | 2″ | 50 | 2 1/2″ | 65 |
Capacities in Gallons per Hour.
| Size No. | Heater Size | Temp. Rise Degree F. | Steam Pressure at Heater Nozzle | ||||||
| 20 | 40 | 60 | 80 | 100 | 120 | 140 | |||
| Approx. Capacity in G.P.H. Using Dry Steam and Full Rated Pressure at Nozzle | |||||||||
| H | 1/2″ | 10 20 40 80 120 |
1344 672 336 168 112 |
2112 1051 525 262 175 |
2816 1408 704 352 234 |
3584 1792 896 448 298 |
4288 2144 1072 536 357 |
4992 2496 1248 624 416 |
5760 2880 1440 720 480 |
| J | 3/4″ | 10 20 40 80 120 |
1664 832 416 208 138 |
2624 1312 656 328 218 |
3520 1760 830 415 276 |
4480 2240 1120 560 373 |
5376 2688 1344 672 448 |
6208 3104 1552 776 517 |
7232 3616 1808 1404 602 |
| K | 1″ | 10 20 40 80 120 |
2176 1088 544 272 181 |
3392 1696 848 424 282 |
4544 2272 1136 568 378 |
5760 2880 1440 720 480 |
6912 3456 1728 864 576 |
8064 4032 2016 1008 672 |
9280 4640 2320 1160 773 |
| L | 1 1/4″ | 10 20 40 80 120 |
2752 1376 688 344 239 |
4288 2144 1072 536 357 |
5824 2912 1456 728 485 |
7360 3630 1815 907 605 |
8832 4416 2208 1104 736 |
10112 5056 2528 1264 876 |
11840 5920 2960 1480 986 |
| M | 1 1/2″ | 10 20 40 80 120 |
3392 1696 848 424 282 |
5312 2656 1328 614 442 |
7232 3616 1808 1404 602 |
9088 4544 2272 1136 757 |
10944 5472 2736 1363 912 |
12608 6304 3152 1576 1050 |
14592 7296 3648 1824 1216 |
| N | 2″ | 10 20 40 80 120 |
5440 2720 1360 680 453 |
8512 4756 2378 1189 792 |
11520 5760 2880 1440 960 |
14528 7264 3632 1816 1210 |
17472 8736 4368 2184 1456 |
19224 9612 4806 2403 1602 |
23360 11680 5840 2920 1946 |
Steam Consumption (in pounds per minute):
| Size No. | Steam Pressure at the Heater | ||||||
| 20 | 40 | 60 | 80 | 100 | 120 | 140 | |
| Steam Consumption in lbs. per min. using Dry Steam | |||||||
| H | 2.1 | 3.3 | 4.4 | 5.6 | 8.4 | 7.8 | 9.0 |
| J | 2.6 | 4.1 | 5.5 | 7.0 | 8.4 | 9.7 | 11.3 |
| K | 3.4 | 5.3 | 7.1 | 9.0 | 10.8 | 12.6 | 14.5 |
| L | 4.3 | 6.7 | 9.1 | 11.5 | 13.8 | 15.3 | 18.5 |
| M | 5.3 | 8.3 | 11.3 | 14.2 | 17.1 | 19.7 | 22.8 |
| N | 8.5 | 13.3 | 18.0 | 22.7 | 27.3 | 31.6 | 36.5 |